Lets get started! Supports Serial over LAN (SoL) and concurrent KVM (cKVM). When BladeCenter decides it will no longer support its storage, server, or network hardware, IT teams are left scrambling trying to figure out what they can do to deal with the problem without breaking the budget. main content, For more information, see the Product Guide. Support for up to 1600 MHz memory speed depending on the processor. Fill out the contact us form and we will help you figure it out. Only one operational memory mode can be enabled on a server, and it is a system-wide setting. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. *** The HS23 (7875, E5-2600 v2) with the Intel Xeon processor E5-2658 v2 (95 W) only supports one DIMM per channel when installed in the BladeCenter H chassis with the standard blower modules or BladeCenter E chassis. DIMMs can be installed one at a time, but for performance reasons, install them in sets of four (one for each of the four memory channels). Requires the 10Gb LOM Interposer Card or Emulex 10GbE Virtual Fabric Adapter II for HS23 be installed in HS23. desk. These new models come standard with 8 GB 1600 MHz, 1333 MHz or 1866 MHz DDR3 VLP RDIMMs, and offer clients either the latest memory technology with Chipkill reliability or dual rank for maximum performance with the Intel Xeon Processor E5-2600 v2 series. Standard 30 mm single-wide form-factor protects your investments by providing compatibility with the BladeCenter H, E, S, and HT chassis. Up to 16 DDR3 DIMM sockets (8 DIMMs per processor) using Very Low Profile (VLP) DIMMs. The HS23 offers two integrated Gigabit Ethernet ports and two integrated 10 Gb Ethernet ports with the integrated Emulex BladeEngine 3 (BE3) controller. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities. If no corresponding where used model for a particular processor is listed, then this processor is available only through Configure to Order (CTO). With its industry-leading RAS features, energy efficiency, outstanding performance, flexible and scalable I/O, and complete systems management, HS23 offers a robust platform optimized for your mission-critical applications. The Sales Manual is updated periodically as new features and options are announced that support these servers. The new Virtual Fabric capable integrated 10 GbE offers extreme speed, and the HS23 is designed with highly scalable I/O to give you a total of up to four 10 Gb physical ports that can be divided into up to 14 virtual ports, as well as the ability to run multiple I/O protocols (FCoE/iSCSI). Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. The following table lists memory options available for the HS23 (7875, E5-2600 v2) server. One CIOv slot (PCIe 3.0 x8) and one CFFh slot (PCIe 3.0 x16). A service technician is scheduled to arrive at the clients location within four business hours after remote problem determination is completed. Built-in Integrated Management Module II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime. A service technician is scheduled to arrive at the clients location on the business day after remote problem determination is completed. The following figure shows the BladeCenter HS23. Figure 2. When one blower fails, the HS23 (7875, E5-2600 v2) with specified processor TDP only supports ambient temperature of up to 28 C when installed in the BladeCenter H chassis with the standard blower modules or BladeCenter E chassis. When your IBM BladeCenter EOL and EOSL dates arrive, dont settle for a costly equipment refresh. An IBM part or feature which replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for System x hardware and selected third-party (Microsoft, Linux, VMware) software. Actual memory speed maximums depend on several factors, as described in "Memory options." Lenovo End of Service Life (EOSL) Devices Home > Third Party Maintenance > Lenovo Hardware Support > Lenovo End of Service Life (EOSL) Is Your Lenovo Device at the End of Service? We focus on making it easy to do business with us. The operating system in the blade server must provide USB support for the blade server to recognize and use USB media drives and devices. 1x E5-2660 v2 10C 2.2GHz 25MB 1866MHz 95W, 1x E5-2670 v2 10C 2.5GHz 25MB 1866MHz 115W, 1x E5-2680 v2 10C 2.8GHz 25MB 1866MHz 115W, 1x E5-2650L v2 10C 1.7GHz 25MB 1600MHz 70W, 1x E5-2697 v2 12C 2.7GHz 30MB 1866MHz 130W, 1x E5-2628L v2 8C 1.9GHz 20MB 1600MHz 70W, 1x E5-2658 v2 10C 2.4GHz 25MB 1866MHz 95W, 2x E5-2670 v2 10C 2.5GHz 25MB 1866MHz 115W, 1x E5-2609 v2 4C 2.5GHz 10MB Cache 1333MHz 80W, 1x E5-2630 v2 6C 2.6GHz 15MB Cache 1600MHz 80W, Intel Xeon Processor E5-2603 v2 4C 1.8GHz 10MB Cache 1333MHz 80W, Intel Xeon Processor E5-2609 v2 4C 2.5GHz 10MB Cache 1333MHz 80W, Intel Xeon Processor E5-2618L v2 6C 2.0GHz 15MB Cache 1333MHz 50W#, Intel Xeon Processor E5-2620 v2 6C 2.1GHz 15MB Cache 1600MHz 80W, Intel Xeon Processor E5-2628L v2 8C 1.9GHz 20MB Cache 1600MHz 70W#, Intel Xeon Processor E5-2630 v2 6C 2.6GHz 15MB Cache 1600MHz 80W, Intel Xeon Processor E5-2630L v2 6C 2.4GHz 15MB Cache 1600MHz 60W, Intel Xeon Processor E5-2637 v2 4C 3.5GHz 15MB Cache 1866MHz 130W, Intel Xeon Processor E5-2640 v2 8C 2.0GHz 20MB Cache 1600MHz 95W, Intel Xeon Processor E5-2648L v2 10C 1.9GHz 25MB Cache 1866MHz 70W#, Intel Xeon Processor E5-2650 v2 8C 2.6GHz 20MB Cache 1866MHz 95W, Intel Xeon Processor E5-2650L v2 10C 1.7GHz 25MB Cache 1600MHz 70W, Intel Xeon Processor E5-2658 v2 10C 2.4GHz 25MB Cache 1866MHz 95W#, Intel Xeon Processor E5-2660 v2 10C 2.2GHz 25MB Cache 1866MHz 95W, Intel Xeon Processor E5-2670 v2 10C 2.5GHz 25MB Cache 1866MHz 115W, Intel Xeon Processor E5-2680 v2 10C 2.8GHz 25MB Cache 1866MHz 115W, Intel Xeon Processor E5-2690 v2 10C 3.0GHz 25MB Cache 1866MHz 130W, Intel Xeon Processor E5-2695 v2 12C 2.4GHz 30MB Cache 1866MHz 115W, Intel Xeon Processor E5-2697 v2 12C 2.7GHz 30MB Cache 1866MHz 130W, 4GB (1x4GB, 2Rx8, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz VLP RDIMM, 8GB (1x8GB, 2Rx8, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz VLP RDIMM, 16GB (1x16GB, 2Rx4, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz VLP RDIMM, 4GB (1x4GB, 2Rx8, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz VLP RDIMM, 8GB (1x8GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz VLP RDIMM, 8GB (1x8GB, 2Rx8, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz VLP RDIMM, 16GB (1x16GB, 2Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz VLP RDIMM, 32GB (1x32GB, 4Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz VLP RDIMM, 500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD, 1TB 7.2K 6Gbps NL SAS 2.5" SFF Slim-HS HDD, 500GB 7.2K 6Gbps SATA 2.5" SFF Slim-HS HDD, 120GB SATA 2.5" MLC HS Enterprise Value SSD, 240GB SATA 2.5" MLC HS Enterprise Value SSD, 480GB SATA 2.5" MLC HS Enterprise Value SSD, 800GB SATA 2.5" MLC HS Enterprise Value SSD, S3500 120GB SATA 2.5" MLC HS Enterprise Value SSD, S3500 240GB SATA 2.5" MLC HS Enterprise Value SSD, S3500 480GB SATA 2.5" MLC HS Enterprise Value SSD, S3500 800GB SATA 2.5" MLC HS Enterprise Value SSD, BladeCenter PCI Express Gen 2 Expansion Blade II, Virtual Fabric Advanced Software Upgrade (LOM), Emulex 10GbE Virtual Fabric Adapter II for HS23, Virtual Fabric Advanced FOD Upgrade (for 81Y3120), Emulex 10GbE Virtual Fabric Adapter Advanced II for HS23, Emulex 8Gb Fibre Channel Expansion Card (CIOv), QLogic 8Gb Fibre Channel Expansion Card (CIOv), io3 Flash Adapters - Enterprise Value (Require the PCI Express Gen 2 Expansion Blade II [68Y7484]), 1250GB Enterprise Value io3 Flash Adapter, 1600GB Enterprise Value io3 Flash Adapter, 3200GB Enterprise Value io3 Flash Adapter, 6400GB Enterprise Value io3 Flash Adapter, io3 Flash Adapters - Enterprise (Require the PCI Express Gen 2 Expansion Blade II [68Y7484]), Blank USB Memory Key for VMWare ESXi Downloads, USB Memory Key for VMWare ESXi 5.1 Update 1. ). We finance your entire solution. {{ leadspaceProductNames }}, contact the IBM IBM may release changes to the Machine Code. BladeCenter HS23 Types 7875 and 1929: Installation and User's Guide. Up to 16 DDR3 ECC memory RDIMMs provide speeds up to 1600 MHz and a memory capacity of up to 512 GB. The new models also offer higher standard memory capacity enabling clients to scale more virtual machines immediately. The Cisco Catalyst Switch Module 3110 for IBM BladeCenter represents the next-generation networking solution for blade server environments. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Note: Consult specific chassis announcements for more information on setup and redundancy. Load balancing and failover teaming support, including adapter fault tolerance (AFT), switch fault tolerance (SFT), adaptive load balancing (ALB), and IEEE 802.3ad. 3-year customer-replaceable unit and onsite limited warranty with 9x5/next business day response time. The BladeCenter HS23 gives you the networking capacity that you need to manage your data center. The power source independent light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components. The BladeCenter HS23 is a next-generation two-socket blade server running the Intel Xeon processor E5-2600 product family. Support for up to 1866 MHz memory speed depending on the processor. To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or IBM . Reading Privileged Memory with a Side Channel 03 Oct 2022. As the global leader in data center and networking optimization, we work with more than 21,000 companies across the globe boosting infrastructure performance and Uptime, maximizing IT staff and stretching budget. The HS23 is a two-socket blade server running the Intel Xeon processor E5-2600 v2 product family. The Intel Xeon processor E5-2600 v2 product family offers significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits. Article Name Date Modified. Virtual Fabric mode or Switch Independent operational mode. The CFFh I/O expansion connector provides I/O connections to high-speed switch modules that are located in bays 7, 8, 9, and 10 of a BladeCenter H or BladeCenter HT chassis. The following table shows the connections between adapters installed in the HS23 blade server to the switch bays in the chassis. For systems that come standard with one Intel Xeon processor, an additional processor may be added by purchasing a supported processor option. Up to eight flash storageadapters supported per one HS23 (two per PCI Express Gen 2 Expansion Blade II and up to four PCI Expansion Blades per HS23). The integrated LSI SAS2004 ROC has the following features: The following table lists the hard drive options that are available for internal storage. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices. New models of the IBM BladeCenter HS23 and HS23E have new memory features that provide additional capabilities to clients. Low-voltage 1.35 V DDR3 memory RDIMMs consume up to 19% less energy than 1.5 V DDR3 RDIMMs. Each expansion blade occupies a bay in the BladeCenter chassis. The HS23 optionally supports the PCI Express Gen 2 Expansion Blade II listed in the following table. These bays are connected to the integrated 4-port LSI SAS2004 6 Gbps SAS/SATA RAID-on-Chip (ROC) controller. Two additional PCIe 2.0 x8 standard form factor slots (slot 1 is full-height full-length, slot 2 is full-height half-length) with the optional PCI Express Gen 2 Expansion Blade II. Ask a Lenovo representative for specifics. The server contains an Integrated Management Module II (IMM2), which is based on the Renesas SH7757 chip, and interfaces with the advanced management module in the BladeCenter chassis. A green cell means that the chassis can be filled with HS23 blade servers up to the maximum number of blade bays in the chassis (for example, 14 blades in the BladeCenter H). This helps to dramatically reduce I/O latency and increase overall system performance. * With Emulex Virtual Fabric Adapters II for HS23 installed in a blade server, two 10 Gb Ethernet ports on the adapter itself are routed to the chassis I/O bays 8 and 10 (unlike other CFFh cards), and two 10 Gb Ethernet ports integrated on a blade itself are routed to the chassis I/O bays 7 and 9. Suggested use: versatile platform to run a broad range of workloads, including infrastructure, virtualization, and enterprise applications. We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. IBMs product lifecycle site now includes the available Eligible Services information for specified IBM Systems (Power, Storage and Z) and Multivendor offerings. The following table lists the system specifications. Only one operational memory mode can be enabled on a server, and it is a system-wide setting. Standard 30 mm single-wide form-factor protects your investments by providing compatibility with the IBM BladeCenter H, E, S, and HT chassis. RAID 0, 1, 1E, and 10 with integrated LSI SAS2004 controller. You can obtain the agreement by contacting your IBM representative or visiting. The optional processor must match the initial processor in each system. Lenovo provides service around the clock, every day, including Lenovo holidays. Up to two vNICs can be configured as an iSCSI or FCoE vNICs (one per port) with optional Advanced Upgrade (90Y9310). Search +1 (800) 230-6638. . If required, On-site Repair is provided, 9 hours per day, Monday through Friday excluding holidays, NBD response. The HS23 server supports theflash storageadapters listed in the following table. https://lenovopress.com/servers/options/backup. When BladeCenter decides it will no longer support its storage, server, or network hardware, IT teams are left scrambling trying to figure out what they can do to deal with the problem without breaking the budget. This limit may be revealed as the device failing to respond to system-generated commands or becoming incapable of being written to. For you, this dedication provides a high-quality, easy, and positive financing experience. The server does interface to the optical drive installed in the BladeCenter chassis media tray if one is installed there. Top view of the BladeCenter HS23. Requires the 10Gb LOM Interposer Card or Emulex 10GbE Virtual Fabric Adapter II for HS23 be installed in HS23. The following has been designated as a consumable or supply item and is, therefore, not covered by this warranty: If required, IBM provides repair or exchange service, depending on the type of warranty service specified below for the machine. For more information, see the following resources: Product families related to this document are the following: Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. The Virtual Fabric capable integrated 10 GbE offers extreme speed, and the HS23 is designed with highly scalable I/O to give you a total of up to four 10 GbE physical ports that can be divided into up to 14 virtual ports, as well as the ability to run multiple I/O protocols (FCoE, iSCSI). In such a case all DIMMs operate at 1.5 V. The maximum number of ranks supported per channel is eight. We finance your entire solution. SoftLayer customers: view the IBM Clouds Docs topic on Getting Support for details Use the search form to find the lifecycle details you need. The key is installed in a USB socket inside the server. For more information about Lenovo warranty service upgrade offerings that are available in your region, visit the Lenovo Services website:https://www-304.ibm.com/sales/gss/download/spst/servicepac. The following rules apply when selecting the memory configuration: * Maximum quantity supported is shown for two processors installed. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions. Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw. With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. Features and specifications. A service technician is scheduled to arrive at the clients location within two hours after remote problem determination is completed. IT Infrastructure Management How to Stay on Budget & Innovate. The server contains an Integrated Management Module II (IMM2), which is based on the Renesas SH7757 chip, and interfaces with the advanced management module in the BladeCenter chassis. Requires the 10Gb LOM Interposer Card or Emulex 10GbE Virtual Fabric Adapter II for HS23 be installed in HS23. Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw. Note: Power supplied through BladeCenter chassis. Simple Network Management Protocol (SNMP) Version 3, Systems Management Architecture for Server Hardware (SMASH), Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state, Remotely accessing the server using the keyboard and mouse from a remote client, Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO image files as virtual drives that are available for use by the server, SUSE LinuxEnterprise Server 11 with Xen for AMD64/EM64T, SUSE LinuxEnterprise Server 11 for AMD64/EM64T, 10 to 35 C (50 to 95 F); altitude: 0 to 914 m (0 to 3,000 ft), 10 to 32 C (50 to 89.6 F); altitude: 914 to 2133 m (3,000 to 7,000 ft). BladeCenter Interoperability Guide Virtualization options. In addition, the HS23 is backward-compatible with all BladeCenter chassis, including the original BladeCenter E. (Some configurations might have restrictions. Up to two processors, 16 cores, and 32 threads maximize the concurrent execution of multi-threaded applications. Two QPI links up to 8.0 GT/s each. Component-sharing design of the BladeCenter chassis provides ultimate power and cooling savings. * Machine Type; see the respectiveProduct Guide in the NAS Storage category(http://lenovopress.com/storage/nas) for available models. Actual memory speed maximums depend on several factors, as described in "Memory options." Calls received after 4:00 pm local time require an extra business day for service dispatch. Therefore, if you are facing IBM EOSL conditions, do not be afraid. A virtual presence capability comes standard for remote server management through the Advanced Management Module (AMM) in the BladeCenter chassis. Height: 245 mm (9.7 in), width: 29 mm (1.14 in), depth: 446 mm (17.6 in). Power, cooling, removable-media drives, external ports, and advanced system management are provided by the BladeCenter unit. The HS23 scales to 18 I/O ports on a single-wide blade with integrated Gigabit Ethernet and 10 Gb Ethernet ports and optional expansion cards, offering the choice of Ethernet, Fibre Channel, SAS, iSCSI, and FCoE connectivity. Maximum configuration (single-wide blade): 5.4 kg (12 lb). We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses. Lenovo warranty service upgrade offerings are region-specific. With BladeCenter S, both GbE ports are routed to the chassis I/O bay 1, and both 10 GbE ports are routed to the chassis I/O bay 2 using the 10Gb LOM Interposer Card (if installed). > servers > bladecenter > Blade - HS23 (BladeCenter) - Type 7875. System x. Table 13. pNIC mode: dual-port 1/10 Gb Ethernet adapter. Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling. The expansion blade provides one full-height and full-length PCI Express x16 (x8-wired) Gen 2 slot and one full-height and half-length PCI Express x16 (x8-wired) Gen 2 slot with a maximum power usage of 75 watts for each slot. With its industry-leading RAS features, energy efficiency, outstanding performance, flexible and scalable I/O, and complete systems management, HS23 offers a robust platform optimized for your mission-critical applications. The size of a rank varies depending on the DIMMs installed. The CFFh I/O expansion connector provides I/O connections to high-speed switch modules that are located in bays 7, 8, 9, and 10 of a BladeCenter H or BladeCenter HT chassis. View all documents published by this author, skip to BladeCenter The following figureshows the top view of the server, indicating key components. The server supports one or two processors. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. Dual independent power and signal connectors to the BladeCenter chassis midplane provide fault tolerance to increase uptime. FastSetup simplifies, automates, and speeds up the deployment process from server power-up to production, making BladeCenter easier to manage, deploy, and maintain. Storage adapters, For more information, see the list of Product Guides in the Blade StorageAdapters category:http://lenovopress.com/servers/blades/hba. IBM Machine Code is licensed for use by a customer on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the customer. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM . Discover how a multinational power technology corporation achieves a seamless migration to a unique IBM i solution with Service Express, saving $2.4 million in OpEx. The key is installed in a USB socket inside the server. Remote server management is provided through industry-standard interfaces: The server also supports virtual media and remote control features, which provide the following functions: The HS23 blade server supports the following operating systems: For more information about the specific versions and service levels that are supported and any other prerequisites, see the Operating System Interoperability Guide:https://lenovopress.com/redposig-operating-system-interoperability-guide. Based upon availability, a CRU will be shipped for next-business-day (NBD) delivery. Up to four expansion blades can be attached to an HS23. Lenovo Services The following table shows the connections between adapters installed in the HS23 blade server to the switch bays in the chassis. IBM BladeCenter includes various sizes of blade servers designed to be adaptive. For attended installation of an operating system, this blade requires a compatible: Unattended or remote installation may be performed without requiring some or all of these components. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors (32 bits per pixel). View The following table lists the external storage systems that are offered by Lenovo that can be used with the BladeCenter HS23in storage solutions. Remote server management is provided through industry-standard interfaces: The server also supports virtual media and remote control features, which provide the following functions: The server supports the following operating systems: For more information about the specific versions and service levels that are supported and any other prerequisites, see the Operating System Interoperability Guide: The IBM BladeCenter HS23 offers performance for value with energy efficiency and density in an all-purpose server that is designed to run a wide variety of workloads. Systems Director Active Energy Manager provides advanced power management features with actual real-time energy monitoring, reporting, and capping features. The BladeCenter HS23 gives you the networking capacity that you need to manage your data center. For more information, see the list of Product Guides in the followingcategories: The following table lists the external backup optionsthat are offered by Lenovo that can be used with the BladeCenter HS23in backup solutions. BladeCenter Interoperability Guide The standard memory configurations are flexible to allow clients to increase their memory capacity to a maximum of 512 GB as their business needs grow. For more information about the BladeCenter S integrated storage, see the BladeCenter S product guide:http://lenovopress.com/tips0977. Up to 3.6 TB with 1.8 TB 2.5" SAS HDDs, or up to 2 TB with 1 TB 2.5" NL SAS/SATA HDDs, or up to 1.6 TB with 800 GB SATA SSDs, or up to 3.2 TB with 1.6 TB 2.5" SAS SSDs. The following figure shows the top view of the server, indicating key components. System x. With BladeCenter S, both GbE ports are routed to the chassis I/O bay 1, and both 10 GbE ports are routed to the chassis I/O bay 2 using the 10Gb LOM Interposer Card (if installed). If memory rank sparing is used, then two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). # Intel Xeon E5-2697 v2 and E5-2690 v2 processors throttle at Steady State at ambient temperature of 31 C in the BladeCenter H chassis. # Intel Xeon E5-2648L (70 W) and E5-2658 (95 W) are robust thermal profile processors used in HS23. This helps to dramatically reduce I/O latency and increase overall system performance. Regarding the use of solid-state disk drives, solid-state memory cells have an intrinsic, finite number of write cycles that each cell can incur. The integrated LSI SAS2004 ROC has the following features: The following table lists the hard drive options that are available for internal storage. The number of HS23 servers supported in each chassis depends on the thermal design power of the processors used in the servers. One HS23 supports up to four PCIe expansion blades (8 slots). ECC, Chipkill, memory mirroring, and memory rank sparing. The HS23 server has two hot-swap drive bays accessible from the front of the blade server. https://lenovopress.com/servers/options/backup. Programs included with this product are licensed under the terms and conditions of the License Agreements that are shipped with the system. Bottom view of the BladeCenter HS23 (shows light path diagnostics panel). CRU information and replacement instructions are shipped with your machine and are available from IBM at any time on your request. Not supported. BladeCenter HS23 models must be installed in a BladeCenter chassis. As a result, each solid-state device has a maximum amount of write cycles to which it can be subjected, documented as TBW (Total Bytes Written). The HS23 is supported in the various BladeCenter chassis listed in the following table. Microsoft Windows Server 2012 R2, 2012, 2008 R2, and 2008 (x64); Red Hat Enterprise Linux 5 (x64), 6 (x86 and x64), and 7; SUSE Linux Enterprise Server 11 (for x86 and AMD64/EM64T) and 12; VMware vSphere 5.1 and 5.5. The effective memory available to the system is only half of that installed. Models E4x and E5x have four DIMMs as standard which means that half of the eight memory channels are unused. Microsoft and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both. Intermix of SAS and SATA HDDs and SSDs is supported. BladeCenter HS23 . IBM will attempt to resolve your problem over the telephone or electronically by access to an IBM website. The following table lists the virtualization options. Support shown is for non-NEBS environments. Not supported. This specialist develops an in-depth understanding of your invoice and payment requirements. ** Processor detail: Model, cores, core speed, L3 cache, memory speed, thermal design power. For models A3x and A4x, the standard DIMM is rated at 1600 MHz, but operates at up to 1333 MHz to match the processor memory speed. The Intel Xeon processor E5-2600 product family improves productivity by offering superior system performance with up to 8-core processors and up to 3.0 GHz core speeds depending on the CPU's number of cores, up to 20 MB of L3 cache, and QPI interconnect links of up to 8 GT/s. Top view of the BladeCenter HS23. Organizations are at different stages of their cloud infrastructure journeys. Contact an IBM representative or reseller for any questions. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/. For more information, see the following resources: Product families related to this document are the following: Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both.